Van Air HB series blower purge regenerative compressed air dryers process larger volumes of compressed air economically, using no compressed air to regenerate the desiccant bed. An externally mounted blower and heater drives hot atmospheric purge air through the desiccant in the off stream tower. A -40°F protects critical equipment and processes.
All Van Air HB series dryers include: fully jacketed insulation on both towers and heater for greatest safety and operating efficiency; a centrifugal blower (3000 scfm and up); Interlock Logic valve control; failure to switch/purge alarm and contact; and polishing purge selector to minimize dew point spikes.
Principle of operation: Wet compressed air is directed through the drying tower where moisture is adsorbed on the desiccant. In the regenerating tower, moisture is stripped from the desiccant by atmospheric air drawn in through the blower and passed over the heater. As the hot purge air flows through the bed, it collects moisture and is discharged through the purge valve(s). The eight-hour NEMA cycle includes four hours of drying, three hours of regeneration and one hour of cooling per tower.
|
|
|
| Features and Benefits |
|
Standard designs 350 to 5,000 scfm; custom units up to 20,000 scfm
Fail to switch light & common alarm contact
On/off switch
Power on light
Heater on light
Blower on light
Activated alumina desiccant
Desiccant fill/drain ports
Stainless steel desiccant screens
Rigid copper pilot air lines
Control air filter
Aluminum jacketed tower, heater and hot piping insulation
460V/3PH/60HZ supply power
115V control power (Control voltage transformer)
Permanently lubricated inlet transfer valve with a position indicator and depressurization safety
Purge exhaust mufflers
PLC control with manual fast advance & hold switches
NEMA 1 control enclosure
Heater power and control power fuses
Heater and blower contactors
Adjustable heater thermostat
Polishing (cool down) purge selector
-40°F dew point
Interlock Logic valve control
Tower mounted pressure and temperature gauges
Controlled re-pressurization and depressurization
Blower motor thermal overload protection
Blower inlet filter
ASME coded pressure vessels
Enamel exterior finish
Tower lifting lugs
|
|
|
| Optional Equipment |
|
NEMA 4 enclosure
Color change moisture indicator
Mounted filters and bypass piping
Audible alarm
Full flow safety relief valves
Digital dew point read out
Dew point demand switching, recommended to minimize dew point spikes at tower switchover
Energy saver. A thermostat registers a rise in purge air outlet temperature, which indicates the bed is regenerated, so the heater is turned off. The relay is automatically reset at the end of the cycle.
High dew point indicator
Sequence lights left/right tower regenerating and/or drying
Steam regeneration
|
|
|
| Applications |
|
Compressed air systems where a -40°F pressure dew point is critical and where no excess air can be spared for desiccant bed regeneration
|
|
|