| Heated Purge Desiccant Dryers |
|
|
View Larger Image |
Ideal for general manufacturing and process industry applications, Van Air HP series externally heated regenerative compressed air dryers provide a low -40°F dew point for superior air line moisture protection while offering the efficiency of convection-heated desiccant regeneration.
All Van Air HP series dryers feature: an isolated external heater for an extra measure of safety; Interlock Logic valve sequencing, for the most reliable tower cycling; and heatless back-up mode, for uninterrupted service while the heater is being serviced.
Principle of operation: Wet compressed air enters the inlet valve and is dried as it flows through a bed of adsorbent desiccant. Dry air exits the outlet valve of the dryer. A small portion (8%) of the outlet air is redirected through the external heater and downward through the off-stream tower to regenerate the desiccant. Wet air is exhausted through the purge valve. The eight-hour NEMA cycle includes four hours of drying, three hours of heating and one hour of cooling per tower. |
|
|
| Features and Benefits |
|
Standard designs 150 to 5,000 scfm
On/off switch
Power on light
Heater on light
Activated alumina desiccant
Desiccant fill/drain ports
Stainless steel desiccant screens
Rigid copper pilot air lines
Control air filter
Aluminum jacketed heater and tower heated zone insulation
460V/3PH/60HZ supply power
115V control voltage transformer
Single external heater
Emergency heatless back-up mode
Permanently lubricated inlet transfer valve with a position indicator and depressurization safety
Purge flow control valve with pressure gauge for flow indication
Purge exhaust mufflers
PLC control with manual fast advance & hold switches
NEMA 1 control enclosure
Heater power and control power fuses
Adjustable heater thermostat
-40°F dew point
Interlock Logic valve control
Tower mounted pressure and temperature gauges
Controlled re-pressurization and depressurization
ASME coded pressure vessels
Enamel exterior finish
Tower lifting lugs
Fail to switch/pressurize light and common alarm contact
|
|
|
| Optional Equipment |
|
NEMA 4 enclosure
Color change moisture indicator
Mounted filters and bypass piping
Audible alarm
Full flow safety relief valves
Digital dew point read out
Dew point demand switching, recommended to minimize dew point spikes at tower switchover
Energy saver. A thermostat registers a rise in purge air outlet temperature, which indicates the bed is regenerated, so the heater is turned off.
High dew point (light and common alarm contact) indicator
Sequence lights, left right tower regenerating and/or drying
|
|
|
| Applications |
|
Installations where a heated dryer is preferred while minimizing both purge loss and capital investment
Installations where -40°F pressure dew point is required
|
|
|
| File Downloads |
|
HP Series Technical Sheet
(PDF, 613K)
Van Air Heated Regenerative Dryers
(PDF, 374K)
|
|
| |