| Internally Heated Desiccant Dryers |
|
|
View Larger Image |
When there is less compressed air to spare, Van Air heated regenerative compressed air dryers provide the solution by requiring less purge air for desiccant regeneration. Compared to a heatless dryer, a Van Air internally heated dryer delivers significant savings through purge air reduction.
Van Air HI series internally heated desiccant dryers supply -40°F pressure dew point air for critical requirements for pneumatic instruments, controls and sensitive process air.
Principle of operation: Wet inlet air flows through the drying tower where moisture is attracted to and adsorbed on the desiccant. Approximately 6% of the dry outlet air, expanded to atmospheric pressure, is diverted to the regenerating tower where it is heated as it flows through a heater isolation tube. This air is then directed through the desiccant bed where it strips off accumulated moisture. Finally, the purge air is exhausted into the atmosphere through a purge valve. The eight-hour NEMA cycle includes four hours of drying, three hours of regeneration and one hour of cooling per tower.
All HI series compressed air dryers include individual heater thermostats. Purge flow rates are adjustable for your operating requirements.
|
|
|
| Features and Benefits |
|
Standard designs 150 to 3000 scfm
On/off switch
Power on light
Heater on light
Activated alumina desiccant
Desiccant fill/drain ports
Stainless steel desiccant screens
Rigid copper pilot air lines
Control air filter
460V/3PH/60HZ supply power
115V control voltage transformer
Permanently lubricated inlet transfer valve with position indicator and depressurization safety
Purge flow control valve with pressure gauge for flow indication
Purge exhaust mufflers
PLC timer with manual & fast advance & hold switches
NEMA 1 control enclosure
Heater power and control power fuses
Heater contactors
Heater safety guards
Adjustable heater thermostats
-40°F dew point
Interlock Logic valve sequencing
Tower mounted pressure and temperature gauges
Controlled repressurization and depressurization
ASME coded pressure vessels
Enamel exterior finish
Tower lifting lugs
Fail to switch light and common alarm contact
|
|
|
| Optional Equipment |
|
NEMA 4 control enclosure
Color changing moisture indicator
Mounted filters and bypass piping
Audible alarm
Full flow safety relief valves
Digital dew point readout
Energy saver light
Sequence lights left/right tower regenerating and/or drying
Dew point demand switching (light and common alarm contact), recommended to minimize temperature spikes at tower switchover
|
|
|
| Applications |
|
Installations where reduced purge air is required
Installations where -40F pressure dew point is required
|
|
|
| File Downloads |
|
HI Series Technical Sheet
(PDF, 574K)
Van Air Heated Regenerative Dryers
(PDF, 374K)
|
|
| |